a.) decrease, velocity spreadRefer to Increased Velocity and Nonlaminar Flow for further study.
b.) increase, turbulence
c.) increase, laminar flow
d.) decrease, gradient flow
You said:
b). increase, turbulence
Correct!
See: Increased Velocity and Nonlaminar Flow
2. The________ is the theoretical maximum frequency that can be accurately measured.
a.) PRFRefer to The Nyquist Limit for further study.
b.) Nyquist limit
c.) scale
d.) Bernoulli equation
You said:
b). Nyquist limit
Correct!
See: The Nyquist Limit
3. Obtaining a true velocity measurement requires a ________ transducer beam.
a.) parallelRefer to The Most Accurate Velocity Measurements for further study.
b.) perpendicular
c.) CW
d.) nonparallel
You said:
a). parallel
Correct!
See: The Most Accurate Velocity Measurements
4. To correct the spectral waveform tracing either ________ or _______.
a.) decrease sample gate depth, increase sweep speedRefer to Aliasing for further study.
b.) change zero line position, use a CW transducer
c.) decrease PRF, use a higher frequency transducer
d.) increase depth, use a lower frequency transducer
You said:
b). change zero line position, use a CW transducer
Correct!
See: Aliasing
5. To detect valvular insufficiency place the sample volume ______ the regurgitant jet.
a.) beyondRefer to Abnormal Flow Patterns for further study.
b.) distal to
c.) proximal to
d.) within
You said:
c). proximal to
Correct!
See: Examples of Abnormal Flow Patterns
6. Which of the images below represent a CW spectrum?
a.) ARefer to Differences in the CW and PW Spectrum for further study.
b.) B
c.) C
d.) D
You said:
b). B
Correct!
See: Differences in the CW and PW Spectrum
7. The CW transducer has
a.) range gatingRefer to The Continuous Wave Transducer for further study.
b.) 126 channels
c.) one crystal
d.) two crystals
You said:
d). two crystals
Correct!
See: The Continuous Wave Transducer
8. The CW tracing appears filled because
a.) of a high Doppler gain setting.Refer to Differences in the CW and PW Spectrum for further study.
b.) the display includes blood flow information from the entire beam.
c.) the display includes blood flow information from range gating.
d.) the flow has multiple abnormal velocities resulting in spectral broadening.
You said:
b). the display includes blood flow information from the entire beam.
Correct!
See: Differences in the CW and PW Spectrum
9. Blood flow traveling toward the transducer results in a(n) _____ waveform.
a.) compressedRefer to The Doppler Effect for further study.
b.) elongated
c.) pitched
d.) decreased
You said:
c). pitched
Incorrect!
See: The Doppler Effect
10. This image demonstrates the proper gate placement for the
a.) aorta.Refer to The Doppler Equation for further study.
b.) TV.
c.) MV.
d.) PA.
You said:
d). PA.
Correct!
See: The Doppler Equation
11. The only advantage of using PW Doppler in an area that exceeds the Nyquist limit is
a.) to use range gating.Refer to Differences in the CW and PW Spectrum for further study.
b.) the accuracy of velocity measurements.
c.) to localize a stenosis.
d.) to decrease aliasing.
You said:
c). to localize a stenosis.
Correct!
See: Differences in the CW and PW Spectrum
12. The width of the sample volume depends upon the transducer _____ and the sample volume_______.
a.) frequency, angleRefer to Range Gating for further study.
b.) beamwidth, size
c.) profile, depth
d.) footprint, number
You said:
d). footprint, number
Incorrect!
See: Range Gating
13. The normal spectral waveform for the Left Ventricular Inflow from the apical position displays ________ the zero baseline.
a.) belowRefer to Examples of Normal PW Doppler Flow Patterns for further study.
b.) above
c.) bidirectionally
d.) around
You said:
a). below
Correct!
See: Examples of Normal PW Doppler Flow Patterns
14. ________ is the unit used to describe the Doppler frequency shift.
a.) VelocityRefer to The Doppler Equation for further study.
b.) MHz
c.) Frequency
d.) Hertz
You said:
a). Velocity
Incorrect!
See: The Doppler Equation
15. Imaging the _________ with the CW transducer requires a suprasternal approach.
a.) descending aortaRefer to CW Transducer Technique for further study.
b.) RVOT
c.) LV inflow
d.) left pulmonary artery flow
You said:
d). left pulmonary artery flow
Incorrect!
16. Transducer frequency and ________ determine the maximum velocity measured during a PW Doppler tracing.
a.) Nyquist limitRefer to Pulse Repetition Frequency for further study.
b.) PRF
c.) aliasing
d.) sweep speed
You said:
a). Nyquist limit
Incorrect!
See: Pulse Repetition Frequency
17. A CW beam interrogating the RVOT and pulmonary artery results in a waveform display _____ the zero baseline.
a.) towardsRefer to Examples of Normal CW Doppler Flow Patterns for further study.
b.) away from
c.) above
d.) below
You said:
d). below
Correct!
See: Examples of Normal PW Doppler Flow Patterns
18. The image below displays blood flow
a.) towards the transducer.Refer to Direction of Flow for further study.
b.) away from the transducer.
c.) that is unidirecitonal.
d.) from a stenotic PA.
You said:
b). away from the transducer.
Correct!
See: Direction of Flow